The F-gas Regulation 2024/573: what changes for cooling in Europe

Which of your units need a leak check?Multi-unit maintenance kitResponsibilities, F-gas leak-check thresholds in kg, calendar, equipment register, contract comparison, specification and report templates

See what is inside, €39Get the guide, €39

Updated · Claude AC · Editorial lead: The Claude AC team · 2 sources cited

Regulation (EU) 2024/573, in force since March 2024, is Europe’s hard schedule for eliminating high-GWP refrigerants: the HFC quota phase-down steepens through the 2020s and reaches full HFC consumption phase-out by 2050, with product bans arriving much sooner. For small splits, the milestones that matter: refrigerants above GWP 750 are already banned in most new single-splits under 3 kg (the rule that killed R-410A in new small units), split air-to-water heat pumps up to 12 kW must go below GWP 150 from 1 January 2027, split air-to-air systems up to 12 kW from 1 January 2029, and splits up to 12 kW may no longer use fluorinated gases at all from 1 January 2035 (Annex IV, point 9, each with a safety exception), pushing the market from R-32 (GWP 675) toward propane R-290 (GWP ~3) and other ultra-low alternatives.

What it means by role

Technician connecting a set of refrigerant gauges to an outdoor unit
Technician connecting a set of refrigerant gauges to an outdoor unit. Photo: U.S. Air Force AFCENT by Airman 1st Class Derrick Bole, public domain, via Wikimedia Commons

Why the EU is doing this

Kilogram for kilogram, R-410A leaked to atmosphere warms like two tonnes of CO₂; cooling’s climate footprint splits between electricity and refrigerant leakage, and the regulation attacks the second half directly while the grid decarbonizes the first. The EU’s bet — visible in every product catalog since 2024 — is that mandated scarcity accelerates the propane-and-low-GWP engineering the industry already knows how to do.

Frequently asked questions

Will my R-410A unit become illegal to run?

No. Bans target placing new equipment on the market and virgin-gas availability, not existing installations. Expect pricier recharges (which, remember, only follow leaks — a sealed system never needs gas) and plan replacements accordingly.

Is R-290 (propane) safe indoors?

Within its engineered limits, yes: charge caps, ventilation and installation rules exist precisely to keep the flammable inventory trivial — a monobloc’s R-290 charge is comparable to a camping canister, sealed in a welded circuit. Certified installation is where the safety lives; DIY is where it does not.

Does F-gas apply in the UK?

Great Britain runs its own retained F-gas regime with a similar phase-down trajectory (Northern Ireland follows EU rules under the protocol); the market effects — R-32 dominance, R-290 arrival — track the EU’s closely.